Before Starting Engine
-
Preflight Inspection
COMPLETE
Use the walker view to inspect the aircraft externally
Check fuel and oil levels
-
Passenger Briefing
COMPLETE
Inform them about security procedures
-
Seats, Seat Belts, Shoulder Harnesses
ADJUST and LOCK
-
Circuit Breakers
CHECK IN
-0.3600
-0.2600
-0.2144
3.0000
-
Electrical Equipment, Autopilot
OFF
-0.3525
0.0525
0.0148
4.7167
Starting Engines
-
Battery Master Switch
ON
-0.3500
-0.3967
-0.2027
2.0413
/controls/electric/battery-switch
property-assign
/controls/electric/battery-switch
true
-
Flashing Beacon
ON
-0.3608
-0.1550
-0.2377
1.7167
controls/switches/beacon-switch
property-assign
controls/switches/beacon-switch
true
-
Generator 1 Switch
ON
/controls/electric/engine/generator
property-assign
/controls/electric/engine/generator
true
-
Generator 2 Switch
ON
/controls/electric/engine[1]/generator
true
property-assign
/controls/electric/engine[1]/generator
true
-
AVIO MSTR Switches 1 and 2
ON
controls/electric/avionics-switch1
true
property-assign
controls/electric/avionics-switch1
1
property-assign
controls/electric/avionics-switch2
1
-
Fuel Prime Pump 1 Switch
ON
/controls/fuel/tank[1]/prime-pump
property-assign
/controls/fuel/tank[1]/prime-pump
1
-
Fuel Prime Pump 2 Switch
ON
/controls/fuel/tank[2]/prime-pump
property-assign
/controls/fuel/tank[2]/prime-pump
1
-
on FND Masterlist: PRIME PUMP caution on
CHECK
-
Engine Switch 1
Idle
nasal
controls/switches/ecp/pos[0]
1
-
Eng. 1 N1, TRQ, TOT and N2
Monitor N1>50%, N2>70%
-
Engine Switch 2
Idle
nasal
controls/switches/ecp/pos[1]
1
-
Eng. 2 N1, TRQ, TOT and N2
Monitor N1>50%, N2>70%
-
Fuel Prime Pump 1 Switch
OFF
/controls/fuel/tank[1]/prime-pump
property-assign
/controls/fuel/tank[1]/prime-pump
0
-
Fuel Prime Pump 2 Switch
OFF
/controls/fuel/tank[2]/prime-pump
property-assign
/controls/fuel/tank[2]/prime-pump
0
-
Transfer Pumps A+F
ON
/controls/switches/fuel/transfer-pump
true
/controls/switches/fuel/transfer-pump[1]
true
property-assign
/controls/switches/fuel/transfer-pump
true
property-assign
/controls/switches/fuel/transfer-pump[1]
true
-
on FND Masterlist: FWD+AFT FUEL PUMP warning off
CHECK
-
Navigation Lights, Strobe
ON as required
controls/switches/nav-lights-switch
1
controls/switches/strobe-switch
1
property-assign
controls/switches/nav-lights-switch
1
property-assign
controls/switches/strobe-switch
1
-
Radios
ON
/instrumentation/comm[0]/volume
0.0
/instrumentation/comm[1]/volume
0.0
property-interpolate
/instrumentation/comm[0]/volume
1.0
0.5
property-interpolate
/instrumentation/comm[1]/volume
1.0
0.5
Before Takeoff
-
Engine 1 and 2 Switches
both FLIGHT
nasal
nasal
controls/switches/ecp/pos[0]
2
controls/switches/ecp/pos[1]
2
-
Seats, Seat Belts, Shoulder Harnesses, Headset Holder
CHECK SECURE
sim/model/bk117/headsetholder/position-deg
0
property-assign
sim/model/bk117/headsetholder/position-deg
0
-
Cabin Doors
CLOSED and LOCKED
-
Flight Controls
FREE and CORRECT
-
Flight Instruments
CHECK and SET
-
Fuel Quantity
CHECK
-
Engine Instruments and Ammeter
CHECK
-
Landing Light
ON
/controls/lighting/landing-lights
property-assign
/controls/lighting/landing-lights
true
-
Strobe Lights
ON
/controls/lighting/strobe
1
property-assign
/controls/lighting/strobe
true
-
Radios and Avionics
SET
-
Autopilot
OFF