Engine Starting Tutorial This tutorial teaches the EC130 B4 Engine Starting Check procedure /sim/current-view/view-number 0 317.3 -49.1 0.0 -0.7 0.0 -3.9 26.2 -4.3331 -0.3504 -0.6702 4.0000 "A/COL LT" On /controls/lighting/beacon 317.3 -49.1 0.0 -0.7 0.0 -3.9 26.2 -4.3331 -0.3124 -0.6702 4.0000 - Switch on fuel pump - "FUEL P" (AltGr-p) - It needs about 30 sec. On the real thing you don't see any effect, on this model the FUEL-P sign on the warning panel may disappear. You have to wait minimum 30sec for the fuelpump to fill up the lines! /controls/fuel/tank/fuellines_filled 0.99 /controls/fuel/tank/fuellines_filled 0.98 326.9 -37.2 0.0 -0.7 0.0 -3.9 32.6 -4.4892 -0.3207 -0.5174 2.0000 - Switch the Start Selector to "FLT" and secure with Guard - /controls/engines/engine/startselector /controls/engines/engine/switchguard 331.4 -22.8 0.0 -0.7 0.03 -3.9 44.1 The engine will spool up now! /engines/engine/n2-pct 66 4.5 -13.1 0.0 -0.67 0.03 -3.93 40 - External power isn't needed anymore- Menu "Toggle External Power" (Alt-p) /controls/electric/external-power 320 -46 0.0 -0.7 0.0 -3.9 31 -4.3322 -0.2992 -0.6669 1.7 - Fuel pump is not needed anymore- the engines suck the fuel now. - switch off "FUEL P" (AltGr-p) /controls/fuel/tank/boost-pump 5 - The engine is running in Idle now- but you can't fly yet! - Continue with "Run Up and Before Takeoff Tutorial" - 347 -25 55 5