Engine Starting Tutorial
This tutorial teaches the EC130 B4 Engine Starting Check procedure
/sim/current-view/view-number
0
317.3
-49.1
0.0
-0.7
0.0
-3.9
26.2
-4.3331
-0.3504
-0.6702
4.0000
"A/COL LT" On
/controls/lighting/beacon
317.3
-49.1
0.0
-0.7
0.0
-3.9
26.2
-4.3331
-0.3124
-0.6702
4.0000
-
Switch on fuel pump - "FUEL P" (AltGr-p)
-
It needs about 30 sec.
On the real thing you don't see any effect,
on this model the FUEL-P sign on the warning panel may disappear.
You have to wait minimum 30sec for the fuelpump to fill up the lines!
/controls/fuel/tank/fuellines_filled
0.99
/controls/fuel/tank/fuellines_filled
0.98
326.9
-37.2
0.0
-0.7
0.0
-3.9
32.6
-4.4892
-0.3207
-0.5174
2.0000
-
Switch the Start Selector to "FLT" and secure with Guard
-
/controls/engines/engine/startselector
/controls/engines/engine/switchguard
331.4
-22.8
0.0
-0.7
0.03
-3.9
44.1
The engine will spool up now!
/engines/engine/n2-pct
66
4.5
-13.1
0.0
-0.67
0.03
-3.93
40
-
External power isn't needed anymore-
Menu "Toggle External Power" (Alt-p)
/controls/electric/external-power
320
-46
0.0
-0.7
0.0
-3.9
31
-4.3322
-0.2992
-0.6669
1.7
-
Fuel pump is not needed anymore- the engines suck the fuel now.
-
switch off "FUEL P" (AltGr-p)
/controls/fuel/tank/boost-pump
5
-
The engine is running in Idle now- but you can't fly yet!
-
Continue with "Run Up and Before Takeoff Tutorial"
-
347
-25
55
5